CTECHI 220 V LiFePO₄ UPS (1–3 kVA) – Tower & 2U Rack-Mount, Online Double-Conversion Battery Backup
Detailed Product Features
- Durable LiFePO₄ Battery Technology
- Equipped with 48 V LiFePO₄ batteries, the system offers up to three times longer lifecycle and backup time compared to traditional lead-acid options.
- Online Double-Conversion & Smart BMS
- Offers full-time pure sine wave output with seamless double-conversion UPS functionality. Integrated Battery Management System (BMS) includes a MODBUS (RS-485) interface and a 4-stage charger (constant current, constant voltage, floating, turn-off) for safe and optimized battery charging.
- Versatile Form Factors
- Available as a compact tower model or a space-saving 2U rack-mount option—ideal for different installation needs from small offices to IT cabinets.
- High Efficiency
- Optimized for energy savings in both normal operation (line mode) and battery-supported mode.
- Wide Input Voltage Range & Cold-Start Capability
- Accepts a broad input range and includes cold-start functionality, enabling the UPS to start up and power connected devices even during complete power outages.
Related Parameters
| Tower Model | Li HV C1K | Li HV C1KS | Li HV C2K | Li HV C2KS | Li HV C3K | Li HV C3KS | ||||||||
| Rack Model | Li HV R1K | Li HV R1KS | Li HV R2K | Li HV R2KS | Li HV R3K | Li HV R3KS | ||||||||
| Capacity | 1KVA/900W | 2KVA/1.8KW | 3KVA/2.7KW | |||||||||||
| AC INPUT | ||||||||||||||
| Wiring | L/N+PE | |||||||||||||
| Rated Voltage | 208/220/230/240VAC | |||||||||||||
| Voltage Range | 90~300VAC | |||||||||||||
| Frequency Range | 40Hz~70Hz | |||||||||||||
| Input Power Factor | ≥0.99 | |||||||||||||
| AC OUTPUT | ||||||||||||||
| Wiring | L/N+PE | |||||||||||||
| Output Voltage | 208/220/230/240VAC | |||||||||||||
| Voltage Regulation | ±1% | |||||||||||||
| Output Frequency | 50/60±4Hz(Sync mode) ; 50/60Hz±0.1%(Free run) | |||||||||||||
| Waveform | Pure sine wave | |||||||||||||
| Distortion(THDV%) | <2%(Linear load); <7%(Non-Linear load) | |||||||||||||
| Overload Capability | 100%~105% continuous;60Sec.@105%~130% rated load;10Sec.@130%~150% rated load;0.3Sec.@>150% rated load. | |||||||||||||
| EFFICIENCY | ||||||||||||||
| Line Mode | 88% | 89% | 90% | |||||||||||
| Battery Mode | 86% | 87% | 88% | |||||||||||
| BATTERY & CHARGER | ||||||||||||||
| Rated Battery Voltage | 48VDC (default for 15cell of LiFePO4 ) | |||||||||||||
| Battery Capacity | 600WH | External battery
depends |
1000WH | External battery
depends |
1000WH | External battery
depends |
||||||||
| Backup Time | >40mins @ half load | >30mins @ half load | >20mins @ half load | |||||||||||
| Charging Current | 4A/8A | |||||||||||||
| Charging Voltage | 52.8V(default for 15cell of LiFePO4 ) / Customized according to battery request | |||||||||||||
| Charger Behavior & Protection | CC. CV. floating. turn-off 4 states
3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface |
|||||||||||||
| HMI | ||||||||||||||
| LED Display | Mains / battery status, load level, battery level, operation mode | |||||||||||||
| LCD Display with LED Indicator | Input mains voltage, frequency, load level, operation mode, health status | |||||||||||||
|
Standards Communication Interface |
(1) RS232 port
(2) Network card: support SNMP,TCP/IP protocol , for remote monitor the UPS via smart phone APP, web page, PC monitor software, support server / NAS shutdown (3) Dry contact interface for BMS control (4) MODBUS For BMS interface |
|||||||||||||
| ENVIRONMENT | ||||||||||||||
| Temperature Range | -10~50°C | |||||||||||||
| Relative Humidity | 0-98%(Non-condensing) | |||||||||||||
| Acoustics Noise | <55dB @ 1 meters | |||||||||||||
| PHYSICAL | ||||||||||||||
| Tower Dimension WxDxH (mm) | C1K: 190x378x318 | C2K: 190x427x318 | C3K: 190x427x318 | |||||||||||
| C1KS: 145x397x220 | C2KS: 145x397x220 | C3KS: 190x378x318 | ||||||||||||
| Rack Dimension WxDxH(mm) | R1K: 440x400x88 (2U) | R2K: 440x500x88 (2U) | R3K: 440x650x88 (2U) | |||||||||||
| R1KS: 440x400x88 (2U) | R2KS: 440x400x88 (2U) | R3KS: 440x400x88 (2U) | ||||||||||||
| Tower N.W (kg) | 10.8 | 5 | 16.5 | 5.5 | 18 | 7.9 | ||||||||
| Rack N.W (kg) | 12.5 | 6.5 | 21.6 | 6.8 | 24.5 | 8.2 | ||||||||
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
5Kwh 10Kwh 51.2V LiFePO4 Rack Battery Home Energy Storage Battery
BT300P
Specification
- Working Voltage: @DC 9V-30V
- Display: 2.4" Color
- Cable Length: 31.5 inches
- Working Temperature: -10℃ to 55℃
- Storage Temperature: -20℃ to 75℃
- Dimension: 8.19*3.94*1.49 inches
- Weight: 16.76 oz.
- Protection: Reverse Polarity Protection
- CCA: 100-2000
- Battery Type: Flooded/AGM/GEL/EFB
- Battery Standard: CCA/CA/BCI/MCA/DIN/IEC/EN/SAE/JIS/G
Packing List
- BT300P
- User Manual
- Carrying Bag
- Printer Paper 3 Rolls
BT600 The Next Step For Battery Testing
-
Specification
- Working Voltage: DC 9V~30V
- Cable Length: 1.8m (70.9’’)
- Working Temperature: -10℃ to 55℃ (14°F to 131°F)
- Storage Temperature: -20℃ to 70℃ (-4°F to 158°F)
- Product Dimensions: 21.79×13.39×5.69cm (8.58×5.27×2.24’’)
- Weight: 550g (19.4 oz)
- Protection: Reverse Polarity Protection
Packing List
- BT600
- Battery Test Cable
- User Manual
- 3 Rolls of Printer Paper
- Mini USB Cable
- Carrying Bag
Ctechi 300w-portable-power-station
JumpSurge3000
-
Specification
- Peak Amps: 3000A
- Capacity (mAh): 24000mAh/ 88.8Wh
- Start-up Capacity: 9L Gas, 7L Diesel
- Input: Type C: PD45W, 5V/3A, 9V/3A, 12V/3A, 15V/3A
- Output--Bidirectional Type C: PD45W, 5V/3A, 9V/3A, 12V/3A, 15V/3A, 20V/2.25A
- Output--USB1: QC18W, 5V/3A, 9V/2A, 12V/1.5A
- Output--USB2: 5V/2A
- Output--DC: 10A Max 16.8V
- Button on the Jump Starter: Power Button*1 BOOST*1
- Length of Clamp Cable: Positive--250mm; Negative--200mm
- Protections: Short Circuit Protection, Over Current Protection, Reverse Polarity Protection, Reverse Charge Protection, Over Temperature Protection, Over Discharge Protection
Packing List
- JumpSurge3000
- User Manual
- Ethylene Vinyl Acetate Carrying Bag
- Battery Clamps
- The adapter
- USB Cable
Tornado120000
-
Specification
Electrical Specifications- Input Voltage: 90~240Vac
- Output Voltage: 11~16.8V 5-120A(adjustable), up to 1700W
- Charging Mode: Supply, Lead-Acid, LiFePO4, Custom, NORM, AGM
- Input: AWG18#, 2m
- Output: Positive AWG4#, 2.2m or 5m; Negative AWG4#, 2.2m or 5m
- Working Temperature: 14°F to 104°F (-10°C to 40°C)
- Storage Temperatue: -4°F to 167°F (-20°C to 75°C)
- Note: To switch the output line length, please change the settings in Output Line Settings.
- Protection: Over-temperature protection, input low voltage protection, overload protection, bad battery protection, short circuit protection, overvoltage protection, reverse connection protection, host abnormality protection.
Packing List
- Tornado120000
- 2m or 5m Battery Clamps
- USB-A to USB-B Cable
- AC Power Cable
- User Manual
- Safety Guide
Tornado90000 Your Battery’s Bodyguard
-
Specification
- Input Voltage: 100-130V or 200-240V
- Adjustable Voltage: 11-15.8V 22-31.6V
- Charging Mode: 12V/24V Mode: SUPPLY/NORM/COLD/BOOST/REPLY/AGM
- Applicable Batteries: 20-2800Ah
- AC Cable Length: 1.8m, Input AWG18#
- Clamp Length: Positive AWG4#, 2.2m; Negative AWG4#, 2.2m
- Protection Rating: IP20 Fan cooled
Packing List
- Tornado90000
- User Manual
- Battery Clamp
- Allen Wrench

Reviews